-
Recent Posts
Recent Comments
- What the Ammonia refrigeration industry can learn from West, TX | TAO Compliance – PSM News for Ammonia Refrigeration on West Texas Damage Photos
- Resource Compliance » Overview of the DHS CFATS Regulation on Did you get a DHS – CFATS/CSAT Top Screen letter?
- FUD in the news! | TAO Compliance – PSM News for Ammonia Refrigeration on West Texas Damage Photos
- FUD in the news! | TAO Compliance – PSM News for Ammonia Refrigeration on Texas Ammonia Explosion Coverage
- OSHA is going to have a field day in 2016 | TAO Compliance – PSM News for Ammonia Refrigeration on Chicago Jewel’s Citation on Operating Procedures and PSI
Archives
- August 2019
- October 2018
- August 2018
- July 2018
- May 2018
- March 2018
- February 2018
- November 2017
- October 2017
- August 2017
- July 2017
- April 2017
- March 2017
- February 2017
- January 2017
- December 2016
- October 2016
- September 2016
- August 2016
- July 2016
- June 2016
- May 2016
- January 2016
- December 2015
- November 2015
- June 2015
- May 2015
- March 2015
- January 2015
- October 2014
- August 2014
- July 2014
- May 2014
- April 2014
- March 2014
- February 2014
- November 2013
- October 2013
- September 2013
- August 2013
- July 2013
- June 2013
- May 2013
- April 2013
- February 2013
- November 2012
- October 2012
- September 2012
- August 2012
- July 2012
- June 2012
- May 2012
- April 2012
- March 2012
- February 2012
- January 2012
- December 2011
- November 2011
- September 2011
- August 2011
- July 2011
- May 2011
- April 2011
- March 2011
- February 2011
- January 2011
- December 2010
- November 2010
- October 2010
- September 2010
- August 2010
- July 2010
Categories
- Community Involvement
- Compliance
- Contractors
- CSB
- Culture
- DHS
- EPA
- General Duty
- General Information
- Good Engineering Practices
- IIAR
- Incidents
- Inspections
- LOTO
- Management of Change
- Mechanical Integrity
- NEP
- Oddities
- Operator Training
- OSHA
- PPE
- RETA
- SOP Development
- SPCC
- Standardization
- System Optimization
- Thermography
- Tier II
- Training
- Uncategorized
Tag Archives: Management of Change
Is a condenser change a Replacement in Kind?
The Question: Imagine a project where you are going to replace an existing condenser with a newer model. Does this “change” trigger the MOC element or does it fall into the Replacement in Kind exemption to the MOC requirement? This … Continue reading
Posted in Compliance, EPA, IIAR, Management of Change, OSHA
Tagged EPA, Management of Change, OSHA, PSM, RAGAGEP, RMP
Leave a comment
Management Of Change (MOC) for Personnel
In response to a recent LinkedIn forum post, here’s a short discussion on why MOC should be implemented for some personnel changes. 1910.119(l)(1) The employer shall establish and implement written procedures to manage changes (except for “replacements in kind”) to … Continue reading
Posted in Compliance, Management of Change, System Optimization
Tagged Management of Change, PSM, RMP
Leave a comment
Why does my PSM program make me review the PHA during any equipment/facility MOC?
Nearly two years ago, I changed the Management of Change Written Plan template in my PSM programs to make a few changes: Removed the “minor change” and “major change” categories. Explicitly require a Process Hazard Analysis review during all equipment/facility … Continue reading
Posted in Compliance, EPA, Good Engineering Practices, Management of Change, OSHA
Tagged EPA, Management of Change, OSHA, PSM, RMP
Leave a comment
Misunderstanding MOC
Recently a valve manufacturer that I respect posted a LinkedIn advertisement for one of their new relief valves. I love new technology so I was really interested in it but noticed something they posted in the graphic: “No PSM Changes … Continue reading
Posted in Compliance, Good Engineering Practices, Management of Change
Tagged EPA, Management of Change, OSHA
Leave a comment